Crewe Surveyors Homebuyers Survey of 1960's Detached Bungalow last refurbished in the 1980's
We found an old and inefficient boiler, unsupported chimney breast, mising lintels, old electical fitings and an invasion of ants.
Free Estate Agents Advertisment!
There is no steel lintel above this replacement window, the frames of which are often not as strong as the original timber ones.
The large glazing unit has also misted due to moisture ingress.
Drainage holes at the bottom of the frame block and the bottom of the glass sits in moisture causing the failure of the seal
High ground adjacent to thin garage walls can cause them to buckle particuarly if there is wet clay soil.
The uniformly green earthing cable sleeve is indicative of a 1970's or 80's system
Fuse box of a similAr age. Fuses are likely to be re-wirable. Critically there is no RCD protection in case of current escape.
Typical 1980's pendant. Very hard to close as they are very shallow and the cap gets obstructed by cables
Old Switch. Porbably original from 1960's
Ant debirs
Single pipe serves both inlet and out let of the radiator. Inefficient and the radiators at the end of the run will not heat up properly.
That the pole can be moved suggests that it is not supporting the chimney breast.
1980's boiler likely to be inefficient but will go for ever and no complicated expensive parts
Low cost Building Surveys and Structural Reports in Coventry
RICS Homebuyers Surveys and Reports in Coventry
Low cost Home Buyers Surveys in Coventry